You could see blue rust all over the distributor, and the joint was also loose, requiring a complete replacement. It was confirmed that the leaky part turned blue. It is said that brass, the material of the distributor, turns blue when water leaks and rusts.Even if you replenish the water, if the error code pops up and the boiler stops, you have no choice but to suspect a leak. Looking at this situation, I conducted a pneumatic test starting with the heating tube, and it was confirmed that the pressure was not maintained. Just in case, I also inspected the direct water pipe and the hot water pipe, but the pressure seemed to be maintained well, so there seemed to be no big problem.When I went to the site of the Gyeongdong boiler error code, the water was leaking downstairs, so the bowl was supported. At first, water permeated the ceiling, and after a day or so, the water droplets began to fall. I went upstairs and checked the boiler, and I found that the Navien boiler error code number 02 was floating. The customer replenished the water several times, but the problem was not solved, and rather, I got a call from the neighbors downstairs.However, if error code 02 appears, it is best to call the boiler driver first, and if it is not a failure of its own, call an experienced leak company to check. In fact, if you handle it incorrectly without understanding the structure of the boiler, it can cause bigger problems.It was decided to remove it because it was a distributor that could not be used anyway. I also told the client that the product was no longer usable and continued to work on it. When the number of replenishment decreases like this, one way is to open an expansion tank that replenishes water and check with a sign pen to see if the water level decreases.When error code 02 appears, it means that there is a problem related to heating water. Unlike hot water, heating water is used to supply water to the floor. In fact, it is normal not to disappear because it continues to circulate and warms the floor without consuming it somewhere. The boiler has an auxiliary tank that stores water, and when the water level goes down, the sensor reacts to replenish the water.Pneumatic inspection is an inspection that checks whether the pressure drops by filling the inside of the pipe with air. If the pressure drops, it can be judged that there is a problem with the pipe, but it is difficult to find a certain leak point, so an additional leak test is required to know the exact leak point. In addition, gas detection and auditory tests were conducted to thoroughly inspect the interior of the house and to confirm that there was a problem with the heating distributor valve.Water flowed from the distributor, which led to a continuous shortage of heating water and a demand for boiler water replenishment. After checking how many distributors there are, I brought a new seven-hole product. The number of distributors varies depending on where the heating water goes, so you need to accurately determine how many and purchase the product.The ceiling downstairs was already wet and the ceiling began to be covered with wallpaper. If the wallpaper had already opened, the entire interior could be wet and the amount of damage could increase, so it was necessary to take prompt action. Fortunately, our company promised to solve it after repairing it because you said you had daily life liability insurance. We also asked the residents of the lower floor to take some of the inconvenience, and we began to detect and repair leaks in earnest.이전 이미지다음 이미지In the sudden cold weather, people are rushing to check boilers and repair pipes to prevent freezing. Kyungdong Navi has a boiler error code that replenishes water, but if problems continue to occur, we will eventually have to detect leaks.The separated hose and coupling were neatly cleaned and a new distributor was connected. You can see the stainless steel distributor neatly connected to the existing pipe.These are heating pipe parts that have been hardened and replaced. There was a possibility of leakage due to the opening of the joint, so I replaced them in advance.The site of the Gyeongdong boiler error code I visited this time solved the leakage of the heating pipe neatly. If you suspect a leak, please contact us and we will sincerely help you.Finally, the boiler heating tube was tested again for pneumatic pressure. It was confirmed that the pressure was well maintained and the floor of the room was warmed up. I explained to the client how to replenish the boiler water and was able to complete the schedule.At the leak site of the apartment house I visited this time, Gyeongdong boiler error code 02 popped up for a few days, so the boiler kept stopping. First, you called the boiler company driver, but he checked the internal parts and exposed pipes, but he said there was no problem and said it would be better to call a leak company. Eventually, the client decided to call us to solve the problem.Stainless steel has higher thermal conductivity than copper distributors and is easier to manage, so it is often used for home boilers. It also has the advantage of being less expensive and not rusting, reducing the probability of problems with piping.